Preview

Minimally Invasive Cardiovascular Surgery

Advanced search

A clinical case of aortic valve replacement with the Medtronic Freestyle stentless bioprosthesis implanted in the "full-root" technique in a patient with a small aortic root

Abstract

There are various options for surgical treatment of aortic valve disease. Each approach has its own advantages and disadvantages. Aortic valve replacement is considered to be the "gold standard" for treating degenerative aortic disease. This procedure is indicated to patients has stenosis or aortic insufficiency. This article reports a clinical case of aortic valve replacement with the Medtronic Freestyle stentless bioprosthesis implanted in the “full root” technique in a patient with a small aortic root. The patient underwent aortic valve replacement with good clinical and hemodynamic results. The article discusses the surgical technique, its effectiveness, as well as indications and contraindications.

About the Authors

S. A. Petko
A.V. Vishnevsky National Medical Research Center of Surgery
Russian Federation

Petko Semen A., M.D., cardiovascular surgeon at the Department of Cardiac Surgery

27, Bolshaya Serpukhovskaya St., Moscow,117997



M. G. Gasangusenov
A.V. Vishnevsky National Medical Research Center of Surgery
Russian Federation

Gasangusenov Magomed G., M.D., cardiovascular surgeon at the Department of Cardiac Surgery

27, Bolshaya Serpukhovskaya St., Moscow,117997



M. M. Anishchenko
A.V. Vishnevsky National Medical Research Center of Surgery
Russian Federation

Anishchenko Maksim M., M.D., Ph.D., cardiovascular surgeon at the Department of Cardiac Surgery

27, Bolshaya Serpukhovskaya St., Moscow,117997



E. S. Malyshenko
A.V. Vishnevsky National Medical Research Center of Surgery
Russian Federation

Malyshenko Egor S., M.D., researcher at the Cardiovascular Surgery Division

27, Bolshaya Serpukhovskaya St., Moscow,117997



V. A. Popov
A.V. Vishnevsky National Medical Research Center of Surgery; Russian Medical Academy of Continuing Professional Education
Russian Federation

Popov Vadim A., M.D., Ph.D., Professor, Head of the Cardiovascular Surgery Division; Professor at the Department of Angiology, Cardiovascular, Endovascular Surgery and Arrhythmology n.a. ac. A.V. Pokrovsky

27, Bolshaya Serpukhovskaya St., Moscow,117997

2/1-1, Barrikadnaya St., Moscow, 125993



A. Sh. Revishvili
A.V. Vishnevsky National Medical Research Center of Surgery;Russian Medical Academy of Continuing Professional Education
Russian Federation

Revishvili Amiran Sh., M.D., Ph.D., Professor, Director; Head of the Department of Angiology, Cardiovascular, Endovascular Surgery and Arrhythmology n.a. ac. A.V. Pokrovsky

27, Bolshaya Serpukhovskaya St., Moscow,117997

2/1-1, Barrikadnaya St., Moscow, 125993



References

1. Astapov DA, Demidov DP, Semenova EI. Prosthesis of aortic valve by stented and stentless biological prostheses: intermediate analysis of results. Grekov's Bulletin of Surgery. 2017;176(4):12- 17. (In Russ.) https://doi.org/10.24884/0042-4625-2017-176-4-12-17

2. Tavakoli R, Jamshidi P, Gassmann M. Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots. J Vis Exp. 2017 May 21;(123):55632. doi:10.3791/55632. PMID28570525;PMCID:PMC5608003. https://doi.org/10.3791%2F55632

3. Rahimtoola SH. The problem of valve prosthesispatient mismatch. Circulation. 1978 Jul;58(1):20-4. doi:10.1161/01.cir.58.1.20.PMID:348341. https://doi.org/10.1161/01.cir.58.1.20

4. Stefanelli G, Pirro F, Olaru A, Danniballe G, Labia C, Weltert L. Long-term outcomes using the stentless LivaNova-Sorin Pericarbon Freedom™ valve after aortic valve replacement. Interact Cardiovasc Thorac Surg. 2018;27(1):116-123. doi:10.1093/icvts/ivy012

5. Doty DB, Cafferty A, Kon ND, Huysmans HA, Krause AH Jr, Westaby S. Medtronic Freestyle aortic root bioprosthesis: Implant techniques. J Card Surg. 1998;13(5):369-375. doi:10.1111/j.1540-8191.1998.tb01099.x

6. Malyshenko ES, Petko SA, Popov VA, Gasangusenov MG, Revishvili ASh. Videoassisted thoracoscopic redo sternotomy for primary dysfunction of the aortic root homograft: a case report. Patologiya krovoobrashcheniya i kardiokhirurgiya = Circulation Pathology and Cardiac Surgery. 2022;26(3):91-96. (In Russ.) https:// doi.org/10.21688/1681-3472-2022-3-91-96

7. Lazuta SS, Spiridonov SV. Options for surgical treatment of aortic valve defects in patients with a narrow fibrous ring. Journal of the Grodno State Medical University. 2019;17(6):630-636. (In Russ.) https://doi.org/10.25298/2221-8785-2019-17-6-630-636

8. Kwasny, L. B. History of heart valve repair / L. B. Kwasny, R. W. Bianco, L. H. Toledo-Pereyra // Heart valves. From Design to Clinical Implantation / eds: P. A. Iaizzo [et al.]. – Boston : Springer US, 2013. – P. 85-120 https://doi.org/10.1007/978-1-4614-6144-9_5

9. Tarasoutchi F. Prosthesis-Patient Mismatch Following Aortic Valve Replacement: Finding Predictors for Prevention. Arq Bras Cardiol. 2020 Jan;114(1):23-24. doi: 10.36660/abc.201907. PMID: 32049166; PMCID: PMC7025307 https://doi.org/10.36660%2Fabc.201907

10. Domoto S, Niinami H, Uwabe K, et al. Comparison of early haemodynamics of 19-mm aortic valve bioprostheses in patients with a small aortic annulus. Interact Cardiovasc Thorac Surg. 2016;22(1):19-25. doi:10.1093/icvts/ivv284

11. He GW, Acuff TE, Ryan WH, et al. Aortic valve replacement: determinants of operative mortality. Ann Thorac Surg. 1994;57(5):1140-1146. doi:10.1016/0003-4975(94)91344-7

12. Kanwar A, Thaden JJ, Nkomo VT. Management of Patients With Aortic Valve Stenosis. Mayo ClinProc.2018Apr;93(4):488-508.doi: 0.1016/j.mayocp.2018.01.020.PMID:29622096. https://doi.org/10.1016/j.mayocp.2018.01.020

13. Nair SK, Sundar R. Mitral and aortic annular enlargement. J Card Surg. 1994 Mar;9(2):131. doi: 10.1111/j.1540-8191.1994.tb00839.x. PMID: 8012101. https://doi.org/10.1111/j.1540-8191.1994.tb00839.x

14. Muratov RM, Titov DA, Kazumyan BV, Sobolev NN. Konno aortoventriculoplasty technique for valvular and subvalvular obstruction of the outflow tract of the left ventricle. Thoracic and cardiovascular surgery. 2016; 58(5): 312-315.(In Russ.)

15. Marathe SP, Chávez M, Sleeper LA, Marx G, Del Nido PJ, Baird CW. Modified Ozaki Procedure Including Annular Enlargement for Small Aortic Annuli in Young Patients. Ann Thorac Surg. 2020;110(4):1364-1371. doi:10.1016/j.athoracsur.2020.04.025

16. Kadyraliev BK, Arutyunyan VB, Chernov II, et al. Neocuspidization of the aortic valve.Patologiya krovoobrashcheniya i kardiokhirurgiya = Circulation Pathology and Cardiac Surgery. 2021;25(2):1118. (In Russ.) http://dx.doi.org/10.21688/1681-3472-2021-2-11-18

17. Chernov II, Kozmin DYu, Makeev SA, Demetskaya VV, Tarasov DG. Immediate results of modified Ross procedure. Patologiya krovoobrashcheniya i kardiokhirurgiya. 2016;20(1):12-18. (In Russ.) https:// doi.org/10.21688/1681-3472-2016-1-12-18

18. Enginoev ST, Kondratiev DA, Zenkov AA, et al. Pulmonary homograft dysfunction after Ross procedure in adults: a single center experience. Russian Journal of Cardiology. 2022;27(8):4804. doi:10.15829/1560-4071-2022-4804. (In Russ.) https:// doi.org/10.15829/1560-4071-2022-4804

19. Albert A, Florath I, Rosendahl U, et al. Effect of surgeon on transprosthetic gradients after aortic valve replacement with Freestyle® stentless bioprosthesis and its consequences: A follow-up study in 587 patients. J Cardiothorac Surg. 2007; 2:40. https://doi.org/10.1186/1749-8090-2-40

20. Ferrari E, Franciosi G, Clivio S, et al. Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch. Interact Cardiovasc Thorac Surg. 2017;24(3):319-323. doi:10.1093/icvts/ivw397

21. Ennker, J., Albert, A., Florath, I. (2010). Medtronic stentless Freestyle® porcine aortic valve replacement. In: Yankah, C.A., Weng, Y., Hetzer, R. (eds) Aortic Root Surgery. Steinkopff. https://doi.org/10.1007/978-3-7985-1869-8_26

22. Ennker J, Meilwes M, Pons-Kuehnemann J, et al. Freestyle stentless bioprosthesis for aortic valve therapy: 17-year clinical results. Asian Cardiovasc Thorac Ann. 2016;24(9):868-874. doi:10.1177/0218492316675244

23. Muratov RM, Lazarev RA, Krestinich IM, et al. Aortic valve replacement with the Medtronic Freestyle prosthesis using a single-row subcoronary technique: surgical technique and mid-term results. Grudnaya i serdechno-sosudistaya khirurgiya. 2008;5:70-72.

24.


Review

For citations:


Petko S.A., Gasangusenov M.G., Anishchenko M.M., Malyshenko E.S., Popov V.A., Revishvili A.Sh. A clinical case of aortic valve replacement with the Medtronic Freestyle stentless bioprosthesis implanted in the "full-root" technique in a patient with a small aortic root. Minimally Invasive Cardiovascular Surgery. 2023;2(2):65-72. (In Russ.)

Views: 209


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.